Blue Coat is aware of the following issues in this release:
- Interface configuration is not saved after upgrading to this release. This occurs if the IP address was not configured for the interface during initial setup (for example, you configured the IP address subsequently through the CLI).
Workaround: After upgrading to this release, configure the IP address for the interface again.(B#210352)
In addition, SGME 6.1.15.1 fixes the following issues:
- RADIUS authorization now works correctly. Previously, all users had level 15 privileges after logging in. Set up RADIUS authentication to Director on Cisco ACS server has been updated with this information. (B#207573, SR 2-986504152)
- The Blue Coat WebFilter (BCWF) database has been updated. (B#207514)
- Director documentation has been corrected to indicate that the ether-1 interface is not supported in Director 6.x. (B#209915)