Getting error: Automation UI tabs could not be found
search cancel

Getting error: Automation UI tabs could not be found

book

Article ID: 163824

calendar_today

Updated On:

Products

IT Management Suite

Issue/Introduction

The customer reported an issue with missing tabs under Manage>Automation Policies page.

Automation UI tabs could not be found.

Environment

ITMS 7.6 HF7 and later

Cause

Unknown.

Resolution

Run from the command prompt as Administrator the following (you may need to browse to the proper drive on your server if it is different than C:):

C:\Program Files\Altiris\Notification Server\Bin\AeXConfig.exe \configure "C:\Program Files\Altiris\Altiris NS Automation\Config\AltirisNSAutomation.config"

 

In case that the actual Automation Policies are also missing, run the following from the command prompt as well:

C:\Program Files\Altiris\Notification Server\Bin\AeXConfig.exe \configure "C:\Program Files\Altiris\Altiris NS Automation\Config\Altiris_NS_Automation_Policies.config"

 

Note: In some unusual instances you may need also run a repair on altiris_nsautomation_7_6_x64.msi (under C:\Program Files\Altiris\Symantec Installation Manager\Installs\Altiris) (or the corresponding installed version):