ProxySG detects low voltage / no input in the SSL card
search cancel

ProxySG detects low voltage / no input in the SSL card

book

Article ID: 172028

calendar_today

Updated On:

Products

Advanced Secure Gateway Software - ASG ProxySG Software - SGOS SG-S500 SG-S400 SG-S200

Issue/Introduction

1. Overall health check status has changed to critical.

2. SSL card temperature statistics shows no input


3. SSL VPTC volage, SSL PLL voltage adn SSL core voltage value is too low



 

Eventlog shows the following error message: 
1. "Health Monitor (CRITICAL): SSL VPTX voltage is 'No Input'"  9 6F0102:1  notifier.cpp:112
2. "Health Monitor (CRITICAL): SSL PLL voltage is 'No Input'"  9 6F0102:1  notifier.cpp:112
3. "Health Monitor (CRITICAL): SSL core voltage is 'No Input'"  9 6F0102:1  notifier.cpp:112

Resolution

This results from an incorrect reading by the BMC (Baseboard Management Controller). 

Please confirm the current BMC version in your sysinfo and compare to the latest version.

If the device is not on the latest version, please upgrade the BMC.

A workaround for this is to reset the BMC.

1. Turn off the box
2. Unplug the power cord and wait for 30-60 seconds to reset and clear the BMC state.
3. After 30-60 seconds, plug the power cord again
4. Power on the box and verify the status